Vector MAXXSST 2200 Manual do Proprietário Página 5

  • Descarregar
  • Adicionar aos meus manuais
  • Imprimir
Vista de página 4
2
1.1 BASIC TOUR OF THE
MAXXSST
2200 INVERTER
AC power is supplied via two standard North American grounded,household-type
receptacles (U-ground) as shown in FIGURE 1 (THE FRONT PANEL). This allows the
connection and operation of most 110 VAC-powered electrical and/or electronic
appliances using a standard plug. Each U-ground receptacle is separately protected
by a 15-amp circuit breaker. For heavy duty applications, appliances or electrical
distribution circuits can be wired directly to the High Output Terminal Block. The terminal
block wires are color-coded: black-hot; white-neutral and green-ground. Note that
the High Output Terminal Block MUST be wired to a user-supplied dual ganged
25 Ampere, 110 volt AC circuit breaker if the terminal block is used. For safety
reasons, the circuit breaker can be a Ground Fault Interrupter (GFI) breaker if the
distribution wiring AC outlets are located near plumbing or where unsupervised
small children will have access to them.
Figure 1. Front Panel.
The rest of the front panel items are: One vertically mounted LED bar voltmeter that
indicates battery voltage measured at the inverter’s DC terminals. One vertically
mounted LED bar ammeter that indicates battery current drawn by just the inverter.
An ON/OFF switch that turns off the inverter circuitry, the cooling fan and AC out-
put. A high-temp LED indicator and Overload LED indicator. If either of these light,
the inverter will automatically shut down until the condition improves.
FIGURE 2 shows the back panel DC connectors and fan locations. Note that
the fan only operates when the inverter temperature rises. It shuts off when cooling
is not required.
GROUNDING
TERMINAL
Figure 2. Back Panel.
25
6.0 SPECIFICATIONS
Maximum Continuous Power . . . . . . . . . . . . . . . . . . . . . . . . .2200 Watts
Surge Capacity (Peak Power) . . . . . . . . . . . . . . . . . . . . . . . . 4500 Watts
No Load Current Draw (switch ON) . . . . . . . . . . . . . . . . . . . . . 1.0 amps
Max. Efficiency . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . approx. 90%
Input Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0-15 VDC
Output Voltage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110 VAC 60 Hz
Low Voltage Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10.6 Volts
Low Voltage Shutdown . . . . . . . . . . . . . . . . . . . . . . 10.0 Volts Auto Reset
Thermal Shutdown . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Auto Reset
Wave Form . . . . . . . . . . . . . . . . . . . . . . . . Modified Sine Wave (MSW)
Front Panel Circuit Breakers . . . . . . . . . . . . . . . . . . . . . . . . . Dual 15-amp
Output Receptacles . . . . . . . . . . . . . . . . . . . . . Two U-ground, 15 ampere,
. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .North American Standard
High Output Terminal Block . . . . . Supplies up to 20 amps to screw terminals
Power Transistor Type . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . MOSFET
Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 23.8 lbs. (10.8 kg)
Length . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20.8 in. (53 cm)
Width . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7.8 in. (20 cm)
Height . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6.30 in. (16 cm)
7.0 SERVICE & PARTS
For service on the MAXXSST
2200, or to purchase a prepared cable set, fuse,
fuse holder, and terminal connectors required for installation, contact the Customer
Service Department at: VECTOR Manufacturing, Ltd. 4140 S.W. 28th Way, Fort
Lauderdale, FL 33312 Tel. (954) 584-4446 • Fax (954) 584-5556
8.0 TROUBLESHOOTING
8.1 Common Problems:
Power Tools and Microwave Ovens Won’t Start
Read the information panel on each power tool carefully to accurately determine
the tool’s input wattage. The MAXXSST
2200 wattage output is sufficient to
operate most power tools and microwave ovens but remember that the power
needed to start the power tool may be as much as 2 to 6 times its continuous
wattage requirements.